Features
Specs
Perf. OEE
Energy
MACHINE FEATURES |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Max Mechanical Output (bph) | 1400 | |||||||||
Machine Dimensions L x W x H (mtr) | 2.3x1.7x1.9 | |||||||||
Dimensions with Performa Feeder L x W x H (mtr) | 4.6x3.2x3.0 | |||||||||
Number of Heating Modules | 3 | |||||||||
Number of Heaters per Module | 8 x 1 kw | |||||||||
PC Industrial Processor | Intel E620T | |||||||||
PC Screen | Touch Screen |
BOTTLE SPECIFICATIONS |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Max. Bottle Diameter (mm) | 120 | |||||||||
Max. Bottle Volume (Liters) | 2 | |||||||||
Max. Bottle Height (mm) | 340 | |||||||||
Max. Perform neck Dimension (mm) | 89 | |||||||||
Max. Perform Height incl. neck (mm) | 160 |
PERFORMANCE OEE |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Mechanical Efficiency (mm) | 95% | |||||||||
Mold Changeover Time (in minutes for 2 technicians) | 30 |
ENERGY |
||||
AIR | Output (Lit. x bph) |
Low Pressure Air for System @ 8 bar (cfm) | Low Pressure Air @ 8 bar with Air Recovery (cfm) | High Pressure Air for Blowing @ 40 bar (cfm) |
0.50 x 1400 1.0 x 1400 2.0 x 1000 |
50 50 50 |
40* 27* 20* |
45 65 80 |
|
INSTALLED ELECTRICAL POWER 415V AC 50Hz ± 5% |
26 kW (Estimated consumption) 55-60% |
|||
WATER (For Over Shields + Mold Cooling @8-12°C & 4 bar pressure) | 30 Lpm |